ITTC
HOME
ABOUT US
SOFTWARE PRODUCTS
CONTACT US
 
写真測定システム(測定精度)

A scale bar (1096mm) is measured from different distances with 400mm reference plate.  10.2M pixel camera is used.

Single View

Distance to object Measure in X Error in X Measure in Y Error in Y
2m1095.763-0.2371096.3960.396
3m1095.853-0.1471095.672-0.328
4m1096.4470.4471095.605-0.395
5m1095.787-0.2131095.812-0.188

Two View

Distance to object Measure in X Error in X Measure in Y Error in Y Measure in Z Error in Z
2m1096.5520.5521096.9810.9811095.470-0.530
3m1096.2910.2911096.8110.8111094.996-1.004
4m1096.3870.3871095.945-0.0551095.327-0.673
5m1096.1190.1191095.568-0.4321095.822-0.178
CMM

Interval

Pair CMM PhotoCalc Deviation
1-2 50.00450.010.006
2-3 49.99950.020.021
3-4 50.03850.040.002
4-5 50.03450.040.006
5-6 50.01450.060.046
7-8 50.00950.040.031
8-9 50.01050.00-0.010
9-10 50.00450.030.026
10-11 50.01549.99-0.025
11-12 49.96550.020.055
13-14 50.02449.97-0.054
14-15 50.02349.98-0.043
15-16 50.00350.040.037
16-17 50.04050.040.000
17-18 50.07750.080.003
19-20 50.00949.99-0.019
20-21 50.00549.99-0.015
21-22 50.01450.01-0.004
22-23 50.06850.110.042
23-24 50.00549.99-0.015
1-7 39.92739.90-0.027
2-8 39.93839.960.022
3-9 39.98240.000.018
4-10 39.96839.970.002
5-11 40.01140.030.019
6-12 39.98740.020.033
7-13 49.99249.99-0.002
8-14 50.00550.00-0.005
9-15 49.99950.000.001
10-16 49.92549.990.065
11-17 49.98649.990.004
12-18 50.05250.080.028
13-19 49.97049.980.010
14-20 49.96749.94-0.027
15-21 49.96049.95-0.010
16-22 50.04149.98-0.061
17-23 49.99550.020.025
18-24 49.95949.970.011
PhotoCalc

▲Top